Water Treatment Chemicals
Cooling Tower chemicals
- Scale Inhibiter: are react with scale( in water). They leads to avoid scale in pipe lines, when they are added to water. therefore free flow the water carries to all heat exchange systems.
- Corrosion Inhibiter: are designed to prevent metal loss and form protective films in metal.it also used oxygen scavenger action from the colling tower water.
- Biocides: are chemicals that kill algae and blue or green algae, when they are added to water. The problem with most algaecides is that they kill all present algae, but they do not remove the toxins that are released by the algae prior to death.
- Bio Dispersent: are reducing agent in CWS. It removes the accumulation of microbiological slimes and bio fouling, When they are added to water.
- Fouling Chemical: Cooling systems provide an ideal environment—warm and wet—for microbes. Bacteria will grow in condensers and cooling tower fill, fungi on and in cooling tower wood and algae on wet cooling tower components exposed to sunlight. Biocide treatment is absolutely essential to maintain cooling system performance and integrity.
- PH Neutralizer: Corrosion is a natural process involving chemical or electrical degradation of metals in contact with water. Acidic water with pH values in the range of 6 to 7 is more corrosive to the metals used in plumbing systems than alkaline water. … Common systems used to treat low pH:
RO PLANT Chemicals
- Highly efficient antiscalant and dispersant for reverse osmosis membrane systems
- Designed for high silica feedwaters
- Very effective antiscalant
- Prevents low production and poor permeate quality
- Prevents downtime and increased costs
- Combats silica fouling
- Is not deactivated in the presence of iron
Chiller chemicals
Chemical treatment (or dosing):
- Proprietary (like NALCOOL) or generic chemicals (like Sodium Silicate, Sodium Nitrite, and Sodium Sulfite) compositions are used to prevent the chiller system from corrosion, scaling, fouling and microbiological growth. How? Mainly in three ways: first, these chemicals react with the pipes to form a protective thin inside layer; second, the chemicals help in maintaining the pH level; and third, the chemicals remove corrosive dissolved oxygen in the water. Dosing pumps are used for applying the predetermined quantities of chemicals at regular intervals
Hot Water Chemicals
- Most iron originates from raw-source makeup water or the corrosion of mild-steel components within a steam and condensate system. Corrosion of mild steel is influenced by factors such as pH, temperature, heat flux, dissolved oxygen, carbon dioxide, flow, ionic strength, suspended solids, and boiler-treatmentchemicals
Boiler Chemicals
- Boiler water must be treated in order to be proficient in producing steam. Boiler water is treated to prevent scaling, corrosion, foaming, and priming. Chemicals are put into boiler water through the chemical feed tank to keep the water within chemical range. … Corrosion is caused by oxygen in the water.
- Boiler water treatment chemicals have been scientifically formulated to improve the operation and maintenance of industrial boiler systems and steam generation plant by proactively managing the problems associated with the use of water including scale formation, metallic corrosion, boiler water carryover and sludge deposition.
- Our high performance boiler water chemicals include single-shot multifunctional treatment products, scale and corrosion inhibitors, oxygen scavengers, alkalinity builders, sludge conditioners, condensate line treatments and more…
ETP & STP Chemicals
We are the prominent suppliers of a wide range of ETP and STP treatment plant chemicals to our clients. Our Range of these are formulated using superior quality chemicals that are procured from reputed certified venders of the industry.
Ferric alum [Ferrous sulphate] :
- We are one of the most reputed firm involved in supplying and trading best quality Ferrous Ferrous Sulphate. These are processed using top quality material and advanced technology by industry experts. AS per the clients requirement we supply these chemicals to our respected clients.
Polyelectrolyte = Anionic / Cationic :
- We are engaged in supplying and trading at best quality Poly Electrolyte – Anionic and Cationic, which is good for its features like durability and superior quality chemicals.
Hydrated Lime :
- We are leading, supplier and trader of Hydrated Lime to our respected clients. It is available in a colourless crystal or white powder. These are formulated using top quality chemicals and procured from calcium oxide.
PAC [Liquid and Powder] :
- Poly Aluminium Chloride: Available in Liquid and Powder forms
- Liquid Poly Aluminium Chloride- PAC is used in water treatment chemicals for effluent treatment and pulp treatment.
- Poly Aluminium Chloride Physical Characteristics
- Al2O3 – 10% Min
- pH – 3-5
UNI-Enzyme I & II :
- An enzyme’s name is often derived from its substrate or the chemical reaction it catalyzes, with the word ending in -ase. Examples are lactase, alcohol dehydrogenase and DNA polymerase. Different enzymes that catalyze the same chemical reaction are called isozymes.
Chlorine :
- Chlorine is a chemical element with symbol Cl and atomic number 17. The second-lightest of the halogens, it appears between fluorine and bromine in the periodic table and its properties are mostly intermediate between them. Chlorine is a yellow-green gas at room temperature.
Bio Culture :
- Enhanced BOD and COD removal
- Builds up MLSS level
- Rapid start-up following initializing and reseeding
- Rapid recovery-following shock loading
- Reduction in filamentation and bulking
- Reduction in sludge volume
- Contains micro-nutrients for the growth of bacteria
- Non-foaming and easy to handle
- Organic Waste + GES SS-28 + O2 = New Cells + CO2+H2O+Energy
Sodium Sulphate :
- Sodium sulfate, also known as sulfate of soda, is the inorganic compound with formula Na₂SO₄ as well as several related hydrates. All forms are white solids that are highly soluble in water.
Nitrate :
- Nitrate is an inorganic compound composed of one atom of nitrogen (N) and three atoms of oxygen (O); the chemical symbol for nitrate is NO3. Nitrate is not normally dangerous for the health unless it is reduced to nitrite (NO2).
Chloride :
- Chloride is an electrolyte. It is a negatively charged ion that works with other electrolytes, such as potassium, sodium, and bicarbonate, to help regulate the amount of fluid in the body and maintain the acid-base (pH) balance
Cooling Tower Spares
Fills Pvc
- The company offers film fill system designed to significantly reduce the risk of biological fouling without sacrificing high performance heat transfer.
- The film fill is a bottom support low-clog log fill configuration. Open, angular cross corrugations allow debris and biological growth foulant to pass, while providing maximum surface area and turbulence to develop efficient heat transfer. Texturing creates thermal capability improvement with little effect on fouling. The fills offers low pressure drop in an aerodynamic, durable design.
Drift Eliminators
- PERFECT offers Drift Eliminators, made out of rigid PVC, are designed to remove entrained particles from air steam efficiently, with minimum pressure drop, thereby reducing the fan power requirement when the air passes through the Drift Eliminator.
- Water droplets are separated from the air drift at the three direction change points on the drift eliminator. Our drift eliminator provides a cellular rugged structure with a very low pressure drop. This results in high drift elimination efficiency while exerting minimum driving force on the fan.
Sprinklers and Water Distribution systems
- Cooling tower sprinkler with rotary head and sprinkler pipe distributes the hot water over the entire space of the filler. Sprinkler pipes are non corrosive, require low pressure to operate and assure uniform water flow with minimal operating pump head.
- Consists of a set of sprinkler pipes and one sprinkler head that is mounted on top of the stand pipe on the cooling tower. The sprinkler is rotated by the pressure of circulating water. There are numerous holes in the sprinkler pipe to allow the water to jet out as the pump impacts rotation.
Cooling Tower Fans
- If you’re looking for high performance, high efficiency and the best price industrial fans, look no further. Perfect’s Axial Flow Fans are the newest and latest large fans to hit the market.Fan blades and hubs are available in custom sizes, colors and configurations.
- With our expertise in the axial fan blades design Perfect use the most efficient aerodynamic profile for the blades designed. Perfect’s aerodynamic hub is the best solution for the reduction of air turbulences near the neck of the cooling tower fan blade.Excellent corrosion resistance is provided for performance that remains same even after long time of operation.
- A true airfoil blade, designed specifically for cooling towers offering efficient quiet operation and long service life. Perfect Cooling Towers is committed to a Total Quality Management Process. Our goal is to deliver the highest quality of products and services to our customers.
COOLING TOWER MOTORS:
- The company offers cooling tower motors that are specially designed flange mounted motors in totally enclosed construction to suit extreme environmental conditions. They are provided with special long shaft construction with external threaded end to directly mount the fan blades this also helps in the better cooling of the motor. Motors are compact in design & less in weight to facilitate easy maintenance.
- Cooling Tower Motors are specially designed ,flange mounted motors in totally enclosed construction to suit air conditioning & refrigeration industries. They are provided with special long shaft construction with external threaded end to directly mount the fan blades. This also helps in the better cooling of the motor. Motors are compact in design & less in weight to facilitate easy maintenance. Cooling Tower Motors available as standard catalouge designs or as custom built.
- The Motor Bearings are sealed with grease for lifetime with seals on shaft to prevent moisture and debris from getting into the bearing.Provision for horizontal lifting is provided as standard, while vertical lifting for easy handling of motor during installation can be provided. They are available as standard catalogue designs or as custom built.